It is a lift control system formed of different electronic modules interconnected by a highly robust communications bus especially designed for the lift. This communications bus enables the number of cables in the lift to be independent from the number of floors and the set of modules connected to the bus, making the system hugely flexible in terms of providing creative solutions to the lift sector.
1 Control panel
2 Hidra 2010 Controller (CCP/PIL)
3 HIDRA Bus
4 Power interface (TPR) (Traction/Hydraulic)
5 Flat loom
6 Cabin (pluggable installation)
7 Inspection box
8 Input / Output Modules (PLR)
9 Distribution board (TBC)
10 Cabin operation panel
11 Displays (DMR, LCD)
12 Autodialer device (SAR)
13 Pushbuttons, lights, audible warning de-vices, etc.
14 Modular shaft installation
15 Elements at every landing
16 Electronic floor module (MPR)
17 Pushbuttons, lights, audible warning de-vices, etc.
| Module | Description |
| (2) CCP PIL | HIDRA 2010 main board with the control program and installation database. It has a 16-character LCD (in-formation and adjustment) and, optionally a LED information panel- |
| (16) MPR | Floor module. Permits the connection of all the user’s labelling elements (pushbuttons, lights, direction arrows, acoustic warning devices, displays, etc.) and safety devices (door presence, interlocking, etc.) on each floor. |
| (8) PLR | Multipurpose 8-input, 8-output module for passenger signalling and special operative, with connection to the HIDRA bus. |
| (12) SAR | Alarm module. Makes it possible to set the alarm off (car, ceiling and pit). Includes intercom system with the machine room, synthesis for car voice messages and telesurveillance event recording. |
| (11) DMR LCD | Graphic displays connected to the HIDRA bus with position, direction and status information. The 3,5” and 5,7” LCDs generate call acceptance and gong sounds. |
| (4) TPR | Interfaces for traction or hydraulic lifts. These boards simplify the COP wiring and facilitate the connection of the lift elements (safety series, trailing flex, etc.). |
| (9) TBC | Wiring distribution board for the car top box to facilitate the connection of all the car elements. |
|
![]() |
| Module | Normative | |
| TRACTION GROUPS | ||
| Hydraulic pump units | TPR, CCP | |
| 1- or 2-AC geared machines | TPR, CCP | |
| Geared or gearless, synchronous or asynchronous traction machines. | TPR, CCP, VVVF | |
| CONTROL | ||
| Non-collective: ‘In use’, door open and travel direction lights on landings. Call acceptance lights in car. One car only. | CCP | |
| Extended non-collective: Call acceptance light on landings and in car. The control does not accept landing calls if any is accepted from the car. Easily to convert into collective. | CCP | |
| Down, up or full collective. | CCP | |
| Up to 22 floors without restrictions. From 23 to 30 floors depending on configuration | CCP, MPR, PLR | |
| Car group (from 2 to 10 cars) without extra dispatcher, based on independent control cabinets linked with 2-wires via the MultiHIDRA bus. | CCP-MH | |
| Dynamic re-assignment of accepted landing calls between cars in the car-group to handle changing conditions and to minimize time and energy demands. | CCP-MH | |
| Option of call request to a specific car within the car group. | CCP, PMR, PLR | |
| In case of a lift breaking down, the landing accepted calls are re-assigned to the other lifts in the group. | CCP-MH | |
| Traffic-light control (red/green) for car lifts (non-collective only) | CCP | |
| SECURITY | ||
| Safety series at 48VAC with standardized isolation distances as for 110VAC | TPR, TBC, CSG | EN 81-1/2 |
| Auto-control of the main contactors and strict compliance of fault analyses | CCP | EN 81-1/2 |
| Adjustable travel time limit | CCP | EN 81-1/2 |
| Inhibition input for over-heating, etc ending the current travel | CCP | EN 81-1/2 |
| Inspection operation limited to the extreme speed-changes and with strict compliance of fault analyses | CCP, TBC | EN 81-1/2 |
| Auto-return (homing) to lowest floor (hydraulic) | CCP | EN 81-2 |
| Manual re-arm required when final limit switch over passed (hydraulic) | CCP | EN 81-2 |
| Automatic re-levelling (hydraulic) with doors open and strict compliance of fault analyses | CCP, CSG | EN 81-2 |
| Re-levelling option with door closed (adjustment) | CCP | |
| Stop precision +/-10mm – Re-levelling precision +/-20mm | CCP | EN 81 A3 |
| Manual rescue energizing the machine in machine roomless lifts | CCP, IDV | EN 81-1 |
| Automatic rescue energizing the machine in machine roomless lifts | CCP, IDV | |
| Automatic rescue in hydraulic lifts (emergency lowering) | CCP, TPR | |
| Evacuation and car parking in case of fire alarm | CCP, PLR | EN 81-73 |
| Evacuation and car parking in case of fire-fighting alarm | CCP, PLR | EN 81-72 |
| Car operation for fire-fighting (with or without fire-fighting switch in car). | CCP, PLR | EN 81-72 |
| Alarm call from inside the car, ceiling and pit in case of be trapped, using an analogical phone line. | CCP SAR | EN 81-1/2 EN 81-28 |
| Trapped alarm phases (start, alarm and end-of-alarm) | SAR | EN 81-28 |
| Automatic test call to the call centre (analogical phone line) | SAR | EN 81-28 |
| Intercom between car and machine room | SAR | EN 81-1/2 |
| Battery control of the alarm device | SAR | EN 81-28 |
| Option to use the GSM/GPRS network for alarm and test calls | SAR, MK775 | EN 81-28 |
| Standardized requirements in radio-electric emission and immunity (EMC) | Todos | EN 12015 EN 12016 |
| CAR POSITIONING | ||
| Position control via two sensors (double row of magnets with 4 or 6 magnets per floor) and 2 bi-stable sensors for extreme speed-change zones. | CCP | |
| Numerical position control with incremental shaft encoder (optional) | CCP, GAP | |
| Repositioning on lowest floor following a breakdown and return of the mains voltage. | CCP | |
| Homing to the adjusted floor (with selection of maximum number of cars on the floor in case of a car group). | CCP (CCP-MH) | |
| Independent return from basement (adjustable) | CCP | |
| DOORS / CAR | ||
| Selection of doors with electrical retiring ramp or mechanical cam (adjustable) | CCP | |
| Double door operator (A and B) management with independent adjustment for each floor and various action options (fixed or according to call, simultaneous or sequential) | CCP | |
| Adjustable number of closing attempts | CCP | |
| Regulation of door close time | CCP | |
| Door reopening for landing calls, always or only without direction (adjustable) | CCP | |
| Door reopening for car call | CCP | |
| Car lighting switch off (optional) | CCP, PLR | |
| USER ASSISTANCE | ||
| Luminous and acoustic call acceptance (adjustable level) if the call can be attended. | CCP, MPR, PLR, RAP | EN 81-70 |
| Next direction indication, luminous (arrows) or acoustic (2-tones gong), on arrival and on departure | CCP, PLR, MPR, LCD | EN 81-70 |
| Single acoustic call acceptance device for the whole of the panel (car and landing) | RAP | |
| Car and landing display with graphic representation of the floor number, car direction and status of the lift (inspection, evacuation, out of order, etc.) | DMR, LCD Mini, LCD 3,5"/5,7" | EN 81-70 |
| Voice synthesis in car for lift messages (floor, opening/closing doors, etc.) or for alarm communication if passengers get trapped in the car. | CCP, SAR | EN 81-70 |
| Call dispatcher adjustable for service optimization in car groups (from 2 to 10), balancing waiting time and energy demand | CCP-MH | |
| Special priority operation in the car (car control/VIP keyswitch) | CCP, PLR | |
| Service cancellation on particular floors, either on a permanent basis (database) or via a remote console. Useful in car groups in irregular buildings. | CCP | |
| Waiting time adjustable between stops | CCP, PLR | |
| Automatic car call cancellation in case of inactivity in the curtain or in the pre-locks (adjustable) | CCP, PLR | |
| Cancellation of landing calls for preparing to test | CCP, PLR | |
| Smooth and comfortable travels in controller configurations with frequency inverters, hydraulic softstop, … | VVVF | |
| FACILITIES FOR THE INSTALLATION OR MAINTENANCE COMPANY | ||
| Options for installations with machine room (traction and hydraulic) or machine rooms less (geared or gearless, control cabinet at landing or integrated in the door frame) | CCP, TPR | |
| Trailing flex with a number of conductors independent of the number of floors | CCP, PLR | |
| Inspection box with pluggable cables for all the car ceiling and operation panel elements | TBC | |
| Modular shaft wiring with just two flat cables pre-cut and ended with connectors. | CCP, MPR | |
| Electronic floor modules for tapping the safety series and landing user signals (pushbuttons, lights, displays, gongs and buzzers, etc.) on each floor | CCP,MPR, | |
| Various stress patterns to test the installation, opening doors or not on each trip and calls from the control cabinet | CCP | |
| Information of the current lift status, event log (30) and tracing samples (inputs and outputs every 0,1s during the previous 3s of each recorded event), displayable on the integrated LCD or in the information panel. | CCP, PIL | |
| Remote surveillance with events dumping (event, date and time). Possibility of initiating a event dumping auto-call when a particular event occurs (adjust) | CCP, SAR | EN 627 |
| Remote control with possibility of modifying usual lift adjustments, resetting, consulting internal log records, provoking calls and checking lift operation | CCP, SAR, SARLink | |
| All adjustments of the control board are protected by a user-modifiable PIN code (the PUK code must be known) | CCP | |
| Same main control board and different interface board for traction and hydraulic lifts | CCP, TPR | |
| Interface for display and voice units of third-party manufacturers | CCP, BCD | |
| Special controls with additional inputs and outputs, on demand and according to client requirements. Incorporation of special requirements into the lift control software. | CCP, PLR-PLC |
HIDRA 2010 can adopt various configurations according with building and end-user requirements:
| Machine Room |
No Machine Room
|
||||
|
MR |
MRL |
MRL-S |
MRL-F |
||
|
Electric |
2V |
x |
|||
|
VVVF |
x |
x |
x |
x |
|
|
Hydraulic |
Direct |
x |
|||
|
E.T |
x |
||||
| MR | The controller cabinet includes control and power elements (contactors, VVVF, etc.) in a conventional wall-mounted cabinet |
| MRL | The controller cabinet includes control and power elements in a single floor cabinet to be fitted on a landing. |
| MRL-S | Small controller cabinet in a landing (control and rescue elements) and a power-elements cabinet to be fitted in the lift shaft head. |
| MRL-F |
Control panel for assembly in a landing doorframe of the landing and a power-elements cabinet to be fitted in the lift shaft head.Available for standard frame size of 120 mm and 150 mm. |
It is a pre-wiring particularly suitable for lifts that have to meet EN81-70 requirements, although due to the reduced installation and starting-up time, it is also suitable for lifts without this requirement.
|
|
|
![]() |
| Module | Description |
| PIL | Diagnosis panel with information about status and events, current and past. Shows the information recorded in the event log in a clear and self-explanatory manner and in different languages. The PIL panel is mounted on the CCP control board and simplifies the interpretation of the information that the control board shows on the LCD display. |
| GAP | A numerical control device for incremental shaft encoders that enables car positioning based on a single magnet per floor (unlocking zone magnet) and 2 bi-stable sensors for detecting extreme zones. Designed to simplify floor level adjustment in installations with many stops, high speed or in cases with short stops distances not always covered by the standard positioning system of 2 sensors and 4 magnets per floor. |
| LCD 5,7 LCD 3,5 |
Graphic blue monochrome LCD displays. Offer information of lift position and status. Include a loudspeaker for acoustic call acceptance and the 2-tone arrival gong. With a PC software can be personalised the screen presentation. |